EXTERNAL I/O
Gas / Liquid / Temperature / Humidity / Electronic Loads / Pressure
Overview
Up to 14 independent inputs and 14 independent outputs
Centralized power supply and emergency shut-off safety control
Full system Run/Standby master
Integrated safety: redundant software or hardwired interlock controls, Emergency stop via front panel mushroom button, Key-switch for secure run access
Hardware safety interlock (HSI) add-on available for additional electrical protection and support
Fully automated and remote control with Fideris Test Suite™ software
Quick swappable modules for zero down time during service
Choose between the following configurations
External Interface: Standard
External Interface: Extended
Inputs / Outputs
| NUMBER OF INPUTS¹ |
Basic: 2 (Internal) Extended: 14 (2 Internal and 12 external) |
| NUMBER OF OUTPUTS² |
Basic: 2 (Internal) Extended: 14 (2 Internal and 12 external) |
| AIR SUPPLY (optional) |
Inlet: 1 Outlet: Up to 7 |
¹Configurable for self-power or external 24 V. Minimum two internal inputs are self-power only.
²Outputs can be configured to one of the following: n.o. relay, n.c. relay switched 24V, switched with the ground. Minimum two internal outputs are switched 24V.
Electrical Specifications
| MAINS INPUT VOLTAGE | 120 or 230 VAC |
| MAINS INPUT FREQUENCY | 50 - 60 Hz |
| MAINS INPUT CURRENT RATING |
13 A, UL 10 A, CE |
| INTERNAL POWER SUPPLY WATTAGE | 750 W |
| INTERNAL POWER SUPPLY OUTPUT | 48 VDC |
Back Panel Connections
| CONTROL POWER - RUN/STANDBY | 4 Position MTA |
| DATA CONNECTION | Ethernet |
| INPUT/OUTPUT CONNECTIONS (Extended version only) | Phoenix 1881655 |
| SUPPLY AIR INLET/OUTLET | 1/8’’ instant tube fittings |
| 48 VDC POWER OUTPUT AND HARDWIRED RUN/STANDBY CONNECTIONS | 4 Position MTA |
| POWER INLET | IEC-320 |
Physical Characteristics
| DIMENSIONS | 2U: 3.5” H x 19” x 21” D |
| SYSTEM WEIGHT | 18 lbs |
| OPERATING CONDITIONS | 40-100°F to 100°F; 0-85% RH non-condensing, indoor use only |
| CLEARANCE FOR OPERATION | Front: 6”, Back: 6”, Sides: 0”, Top: 0” |